Skip to content

Insulating castables

Insulating castables contain lightweight to ultra-lightweight constituents, which give them a low bulk density and therefore lower thermal conductivity. They are used primarily for insulation.

5 grades · 1000–1650 °C

Grades compared

Technical data of 5 grades, sortable
λW/(m·K)
Megrit 100-0,5 0-4 1000no data1.5281814600 °C 0.181000 °C 0.24
Megrit 120-0,9 0-5 12001050835373no data
Megrit 135-1,3S 0-5 135014402242423.7600 °C 0.441000 °C 0.49
Megrit 150-1,5 0-5 150016001462281.9600 °C 0.491000 °C 0.55
Megrit 165 16501600186727.91800 °C 1.151200 °C 1.36

Key:

MST
Maximum service temperature in °C
CT
Classification temperature in °C
BD
Bulk density in kg/m³
CCS
Cold crushing strength in N/mm²
Al₂O₃, SiO₂, Fe₂O₃
Chemical composition in %
λ
Thermal conductivity in W/(m·K) at the stated temperature

All technical data are typical values. The properties agreed in the quotation and order confirmation are binding.